Simons Voss Technologies Palm LDB Version 1.40 Instalační manuál Strana 200

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 219
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 199
VdS Shunt lock function 3066
Page 25
4.2 Installing the Activation Unit (MA and SA)
You should install the activation unit (AU), no matter whether it is a master activation
unit MA or slave activation unit (SA), above the door case and above the locking
cylinder. In any case, the distance to other SimonsVoss components
must be at least
1 m or approximately 40 inches (refer to the drawing).
Only in this way can you rule out mutual interference influences.
If you install it above the door case, align the activation unit so that the two fastening
screws lie in a horizontal line. This eliminates interference when the door is used in
the normal way. (Refer to the drawing below.)
This installation is done without the antenna extender and with jumper B2 is inserted
(max. range). Because this (simple) installation method allows the system t
Min. 100 cm
(40 inches)
Digital
cylinder
Max. 30 cm (12 inches)
DA
AU
Zobrazit stránku 199
1 2 ... 195 196 197 198 199 200 201 202 203 204 205 ... 218 219

Komentáře k této Příručce

Žádné komentáře