Simons Voss Technologies Palm LDB Version 1.40 Provozní pokyny

Procházejte online nebo si stáhněte Provozní pokyny pro Software Simons Voss Technologies Palm LDB Version 1.40. Simons Voss Technologies Palm LDB Version 1.40 Operating instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Manual – LDB 1.5

Manual – LDB 1.5 Published: December 2006

Strany 2

Manual – LDB 1.5 Page 10 101.3 Testing the Configuration tool You can test the Configuration tool you have connected at Programming > Check

Strany 3

Manual – LDB 1.5 Page 100100Before importing, you first have to set up a new Lock System in LDB (in this case for Sampleson Ltd.), along with a p

Strany 4

Manual – LDB 1.5 Page 101101 12.3 Importing a complete Lock Plan You can also import a Lock Plan created by a customer – one set up in Excel, f

Strany 5

Manual – LDB 1.5 Page 102102 In the Import window, select the function ‘Lock Plan’ then define the Separator (semi-colon, tab, comma) used to di

Strany 6

Manual – LDB 1.5 Page 103103 12.4 Overview of lock properties You can obtain a precise listing of the lock and transponder data using the exp

Strany 7

Manual – LDB 1.5 Page 104104 You can select several locks at once using the Ctrl key. Confirm with OK. Place a check alongside the lock prop

Strany 8

Manual – LDB 1.5 Page 105105 The Save as window will open. Name the file (i.e. Sampleson.csv), and then save it in CSV format. Open Windows E

Strany 9

Manual – LDB 1.5 Page 106106 12.5 Overview of transponder properties You can enter additional data on every transponder, such as private addre

Strany 10

Manual – LDB 1.5 Page 107107 When entering the address, you will need to press Ctrl and Enter in order to move down a line. Choose File > Ex

Strany 11

Manual – LDB 1.5 Page 108108 You can select several transponders at once using the Ctrl key. Confirm with OK. The Transponder properties window

Strany 12

Manual – LDB 1.5 Page 10910912.6 Exporting a complete Lock Plan You can export a complete Lock Plan into a program such as Excel, make changes

Strany 13

Manual – LDB 1.5 Page 11 11software on the Internet at www.simons-voss.us (Products – Downloads folder). To install a newer version of the so

Strany 14

Manual – LDB 1.5 Page 110110Assign the character which is to be used to signify access authorization in Microsoft Excel. Click on Continue and se

Strany 15

Manual – LDB 1.5 Page 111111 13.0 Views 13.1 Cross-hairs, label boxes, ID numbers Cross-hairs The cross-hairs make it easier to check whether

Strany 16

Manual – LDB 1.5 Page 11211213.2 Installed lock lengths You can display the installed lengths of the locks behind each lock name. Choose View

Strany 17

Manual – LDB 1.5 Page 113113 Another way of printing out a list of authorized locks is while you are programming the transponder. Click on the

Strany 18

Manual – LDB 1.5 Page 11411413.4 Authorizations for a lock You can obtain a list of the people authorized to operate a particular lock as foll

Strany 19

Manual – LDB 1.5 Page 11511513.5 Transponder groups You can obtain information about which Transponder groups locks belong to in the same wa

Strany 20

Manual – LDB 1.5 Page 116116 14.0 Special transponders 14.1 Password transponders Instead of entering the password via the keyboard, you can pr

Strany 21

Manual – LDB 1.5 Page 117117 14.2 Activation transponder This transponder is used in an emergency to activate digital US Locks if they have b

Strany 22

Manual – LDB 1.5 Page 118118 14.3 Creating a CD transponder (not compatible with SmartCD) PalmCDs can also be used as transponders in your Loc

Strany 23

Manual – LDB 1.5 Page 119119 15.0 Setting up a network 15.1 Setting up a CentralNode Connect the CentralNode to a free serial port on your PC

Strany 24

Manual – LDB 1.5 Page 12 12 2.0 Setting up a Lock Plan 2.1 Creating a new Lock System Choose New > Lock System. Enter the name of the Lock

Strany 25

Manual – LDB 1.5 Page 120120 15.2 Network Setup The Network setup function is used to configure the network. Changing these settings can c

Strany 26

Manual – LDB 1.5 Page 12112115.3 Registering a network node You must tell the software which nodes are installed in the network. Lock Nodes all

Strany 27

Manual – LDB 1.5 Page 122122 Select the action you would like to perform. Next you will receive a list of all the Lock Nodes that have been su

Strany 28

Manual – LDB 1.5 Page 12312315.5 Assigning/changing the network password Data communication between the software and the individual nodes can b

Strany 29

Manual – LDB 1.5 Page 124124Check the Successful list carefully. If, even though the System has already been programmed, an ‘unknown lock’ appear

Strany 30

Manual – LDB 1.5 Page 125125 Yellow Problem in the radio connection between Lock Node and lock (caused by an open door, for example). Red Conn

Strany 31

Manual – LDB 1.5 Page 12612615.8 Removing network nodes Select the lock whose network node you would like to remove. Choose Options > Network

Strany 32

Manual – LDB 1.5 Page 12712715.10 Input/output This is where you can adjust the inputs and outputs of the Lock Node. If you would like to acti

Strany 33

Manual – LDB 1.5 Page 128128SId ID number of the Lock System LId ID number of the lock GId Group ID of the network node MId Member ID

Strany 34

Manual – LDB 1.5 Page 129129 Make the changes you require and confirm with OK. 15.12 Configuring SMS messages Choose Options > Unified m

Strany 35

Manual – LDB 1.5 Page 13 13 If you clicked OK & Continue, you can now define more locks. Simply enter the door name and confirm by pressin

Strany 36

Manual – LDB 1.5 Page 130130 15.13 Configuring e-mail Choose Options > Unified messaging. In the Message Systems box, click the E-mail bu

Strany 37

Manual – LDB 1.5 Page 131131Click the New button. Enter the address to which the message is to be sent (i.e. [email protected]) E

Strany 38

Manual – LDB 1.5 Page 132132 You can change the path by clicking the Log file button. Confirm your entries by clicking OK. All events shou

Strany 39

Manual – LDB 1.5 Page 133133 16.0 Organizing a network 16.1 Assigning a Network Administrator password The administration of a network can be

Strany 40

Manual – LDB 1.5 Page 134134All of the nodes in a network: Click All groups and All nodes, followed by the OK button. Select the action you wo

Strany 41

Manual – LDB 1.5 Page 13513516.4 Program Lock System Open your Lock System using the password and make the changes you require – such as changi

Strany 42

Manual – LDB 1.5 Page 136136 Press the Programming button. The locks will then be programmed one after the other. 16.5 Retrieving individual A

Strany 43

Manual – LDB 1.5 Page 137137 16.6 Retrieving multiple Access Lists simultaneously You can retrieve the Access Lists from several locks at the

Strany 44

Manual – LDB 1.5 Page 138138 The Successful window will contain all the locks from which data has been successfully retrieved. If an Error has o

Strany 45

Manual – LDB 1.5 Page 139139 You will receive a list of the most recent accesses. The number of accesses saved can be set between 0 and 10,000.

Strany 46

Manual – LDB 1.5 Page 14 14 If you are entering room numbers, then you can set up several locks easily using the copy function. Enter the room n

Strany 47

Manual – LDB 1.5 Page 140140 The software will use the date and time stored in your computer, so you should check these before synchronizing.

Strany 48

Manual – LDB 1.5 Page 141141 Assign a name to this task (i.e.Retrieve Access Lists). If you would like to activate the task at a later stage, un

Strany 49

Manual – LDB 1.5 Page 142142 Remember that a task can take several minutes, so you should plan your tasks carefully so as not to overburden your

Strany 50

Manual – LDB 1.5 Page 143143 Clicking the Stop button will halt the Task Manager, and clicking Start will make it start up again. You can plan o

Strany 51

Manual – LDB 1.5 Page 144144 You can obtain an overview of all your tasks by creating a Log file. This text file can be opened and evaluated usi

Strany 52

Manual – LDB 1.5 Page 145145 17.0 Event Manager 17.1 Definition This function is used to create logical links between an event and a response.

Strany 53

Manual – LDB 1.5 Page 146146Overview of events: Input event The input signal changes at a network node Key combination Two keys are pressed o

Strany 54

Manual – LDB 1.5 Page 14714717.4 Run file This response launches an executable program. Examples: a.) You can write a program (batch file) w

Strany 55

Manual – LDB 1.5 Page 148148 Some settings must first be made under Options > Unified Messaging > E-mail in order for e-mails to be sent

Strany 56

Manual – LDB 1.5 Page 149149 Click the Edit button and select the lock(s) involved. Confirm your entries by clicking OK.

Strany 57

Manual – LDB 1.5 Page 15 15 2.3 Inserting divider bars Divider bars are used to categorize locks – into particular areas, for instance (build

Strany 58

Manual – LDB 1.5 Page 150150 17.7 Configuring network messages A message is sent to a network computer which is displayed in a special Simons

Strany 59

Manual – LDB 1.5 Page 151151Confirm your entries by clicking OK. 17.8 Send SMS You can send an SMS to a mobile phone. Select SMS as the type.

Strany 60

Manual – LDB 1.5 Page 152152 17.9 Creating a log file This file displays the events. Events are recorded in a table and can be edited using a

Strany 61

Manual – LDB 1.5 Page 153153 You can set a time limit to the initiation of a reaction to an event. For example, it is often only important if a

Strany 62

Manual – LDB 1.5 Page 154154 Now all you have to do is select the event and configure it. There are four types of events available, and the pages

Strany 63

Manual – LDB 1.5 Page 155155 Select the associated lock, and configure the time if necessary. Select the action and confirm with OK. 17.12 Co

Strany 64

Manual – LDB 1.5 Page 156156Select the associated lock, and configure the time if necessary. Select the action and confirm with OK. 17.13 Sett

Strany 65

Manual – LDB 1.5 Page 157157 Make the same settings to deactivate the timer, since you only want a response if the door remains open and the sti

Strany 66

Manual – LDB 1.5 Page 15815817.14 Entry event You can only define a reaction to an access event if you have set the software to continuously ret

Strany 67

Manual – LDB 1.5 Page 16 16 2.4 Setting up transponders Select New > Transponder. Enter the name of the first transponder owner. This name

Strany 68

Manual – LDB 1.5 Page 17 17 2.5 Authorizing transponders for specific times and dates Choose New > Transponder. Allocate a name (i.e., Ass

Strany 69

Manual – LDB 1.5 Page 18 18 2.6 Authorizing transponders Authorization is allocated at the click of a mouse, and can be changed later if requi

Strany 70

Manual – LDB 1.5 Page 19 19 This is a very easy way of authorizing to several transponders. You can also authorize transponders individually us

Strany 71

Manual – LDB 1.5 Page 2 21.0 Commissioning ...7 1.1 Standard toolbar

Strany 72

Manual – LDB 1.5 Page 20 20 Beneath the ”Approve for lock units”’ area, click on the Manage button. Select the locks for which this transponder

Strany 73

Manual – LDB 1.5 Page 21 21 2.8 Programming locks Once you have finished making changes to the Lock System, you must then approve it. Locks ca

Strany 74

Manual – LDB 1.5 Page 22 22You can see if a Lock System is approved, because, when it is, there will be a check after its name (i.e., to the left

Strany 75

Manual – LDB 1.5 Page 23 23 The yellow flash behind the lock disappears, and the cross appears in bold. If you are programming a lock or Smar

Strany 76

Manual – LDB 1.5 Page 24 24 Once you have programmed all the locks, close the window by clicking on Exit. You can always add new locks at a lat

Strany 77

Manual – LDB 1.5 Page 25 25 Enter the password for your Lock System. The word is concealed by asterisks as you enter it to prevent unauthorized

Strany 78

Manual – LDB 1.5 Page 26 26 Hold the transponder in front of the Config Device, click Program, and briefly press the button on the transponder.

Strany 79

Manual – LDB 1.5 Page 27 27Open the Lock System for editing (Authorize > Open Lock System). A new lock is added above the selected lock. Cli

Strany 80

Manual – LDB 1.5 Page 28 28transponder. Click the right-hand mouse button then choose New > Transponder. Enter the name of the new transponder

Strany 81

Manual – LDB 1.5 Page 29 29Beneath Transponders, click the Manage button. Then select the new transponder (i.e., 12032 Walter Summers). Click the

Strany 82

Manual – LDB 1.5 Page 3 34.6 Digital SmartRelay – Access control ... 50 4.7 Digital SmartRelay – Ti

Strany 83

Manual – LDB 1.5 Page 30 30 2.12 Changing authorizations Choose Authorize > Open Lock System. Enter the password for your Lock System and co

Strany 84

Manual – LDB 1.5 Page 31 31 3.0 Time zone management Electronic access control systems provide the ability to limit access by time and date. T

Strany 85

Manual – LDB 1.5 Page 32 32 Click on the first group, then on the day or days of the week. By keeping the mouse button pressed you can select s

Strany 86

Manual – LDB 1.5 Page 33 33 If you would like to specify another day of the week for the same group, then click on it – Saturday for example. I

Strany 87

Manual – LDB 1.5 Page 34 34 Allocate the time zones for the next groups, as described above. A maximum of 126 switching points (authorize or bl

Strany 88

Manual – LDB 1.5 Page 35 35 The public holidays shown on the right-hand side are treated like Sundays. Since Group 1 does not have authorization

Strany 89

Manual – LDB 1.5 Page 36 36 The holiday you have created (i.e., Works holiday) will now appear together with the other selected public holidays

Strany 90

Manual – LDB 1.5 Page 37 37If you do not want to make any more changes to the holiday list, then confirm with OK. 3.3 Changing the holiday lis

Strany 91

Manual – LDB 1.5 Page 38 38 Now press Save. Confirm the holiday list with OK. 3.4 Integrating a time zone plan Choose the holiday list you h

Strany 92

Manual – LDB 1.5 Page 39 39 If you do not want to make any more changes, then click on Ready. If there are still changes to be made, select the

Strany 93

Manual – LDB 1.5 Page 4 48.0 Replacing a component...79 8.1 Replacing a lock...

Strany 94

Manual – LDB 1.5 Page 40 40 A programming flash will appear behind the name of the lock. This means that the lock has to be reprogrammed. Approv

Strany 95

Manual – LDB 1.5 Page 41 41Choose Edit > Properties. Click on the Time control tab and choose the Lock System and the relevant group (i.e., Lo

Strany 96

Manual – LDB 1.5 Page 42 42 The transponders that have a specified time zone control must now be reprogrammed.

Strany 97

Manual – LDB 1.5 Page 43 43 4.0 Configuring the components 4.1 Digital US Lock If necessary, you can configure digital US Locks to remain eng

Strany 98

Manual – LDB 1.5 Page 44 44 Approve your Lock System, and then program the digital US Lock. 4.2 Digital control unit with pulse control The

Strany 99

Manual – LDB 1.5 Page 45 45 Approve the Lock Plan and program the digital control unit. 4.3 Digital control unit as flip-flop The relay is p

Strany 100

Manual – LDB 1.5 Page 46 46 Choose Edit > Properties. Click on the Configuration tab and check the Flip-flop box. Confirm with OK and approve

Strany 101

Manual – LDB 1.5 Page 47 47 Confirm with OK. Choose Group 5 self-locking and the Days of the week you require. Next, mark the times at which yo

Strany 102

Manual – LDB 1.5 Page 48 48Under Time zone plan, select the Plan you have created. Click on Accept. Choose the Configuration tab. Using the

Strany 103

Manual – LDB 1.5 Page 49 49 Confirm with OK. Approve your Lock System and program the digital control unit. 4.5 Digital SmartRelay If SmartRe

Strany 104

Manual – LDB 1.5 Page 5 513.1 Cross-hairs, label boxes, ID numbers ... 111 13.2 Installed lock lengths.

Strany 105

Manual – LDB 1.5 Page 50 50 4.6 Digital SmartRelay – Access control SimonsVoss in the United States primarily sells the Advanced version (S

Strany 106

Manual – LDB 1.5 Page 51 51 4.7 Digital SmartRelay – Time zone control SimonsVoss in the United States primarily sells the Advanced version (SR

Strany 107

Manual – LDB 1.5 Page 52 52If you would like the SmartRelay to transmit transponder data to a non-SimonsVoss system and upon authorization from t

Strany 108

Manual – LDB 1.5 Page 53 53Normally, a transponder cannot be used during the unlocked period (day). However, if you want to enable the door to be

Strany 109

Manual – LDB 1.5 Page 54 54 4.13.3 No acoustic programming confirmations If you do not want the connected buzzer / beeper to respond when the Sm

Strany 110

Manual – LDB 1.5 Page 55 55 In the SmartRelay’s configuration screen, you can define the number of SmartOutput Modules. A maximum of 16 SmartOut

Strany 111

Manual – LDB 1.5 Page 56 56 In the above example it is therefore the first output of the first SmartOutput Module. A maximum of 16 SmartOutput M

Strany 112

Manual – LDB 1.5 Page 57 57 This automatically changes all of the names of the SmartOutput Modules linked to the SmartRelay. SmartOutput Module

Strany 113

Manual – LDB 1.5 Page 58 58 The time an elevator button is lit can be set as the pulse length of the Output Module concerned, whereas the flashi

Strany 114

Manual – LDB 1.5 Page 59 59Elevator main building → Name of the lock of the SmartRelay belonging to the Output Module Mod#0 → Address of the Smar

Strany 115

Manual – LDB 1.5 Page 6 616.7 Synchronizing the time... 139 16.8 Task Manager .

Strany 116

Manual – LDB 1.5 Page 60 60 In the Lock properties of the SmartRelay (i.e. for the Admin building lift), choose Configuration > Advanced funct

Strany 117

Manual – LDB 1.5 Page 61 61If you need to reduce the number of existing SmartOutput Modules in your Lock System, you can change the total number

Strany 118

Manual – LDB 1.5 Page 62 62 Moving a SmartRelay with SmartOutput Modules If you want to move the SmartOutput Modules within a Lock System – for

Strany 119

Manual – LDB 1.5 Page 63 63 If the Output Modules are programmed using a PDA, then those modules are not offered when exporting the data to the P

Strany 120

Manual – LDB 1.5 Page 64 64 The target and current data remain unchanged when you click this button (the current data is not set to ‘zero’). Onc

Strany 121

Manual – LDB 1.5 Page 65 65 5.0 Master level 5.1 Setting up a master level A master locking level has to be set up if you want a transponder

Strany 122

Manual – LDB 1.5 Page 66 665.2 Setting up a master transponder Choose New > Transponder. Enter the name of the owner. (i.e. Brian Wiberg) U

Strany 123

Manual – LDB 1.5 Page 67 67 You can also program a master transponder as a normal transponder in two other Lock Systems. A transponder can only

Strany 124

Manual – LDB 1.5 Page 68 68 Finally, program the locks that require programming. 5.4 Deleting a level You can obtain an overview of the maste

Strany 125

Manual – LDB 1.5 Page 69 69 Close the window with Exit. 5.5 Changing the password Choose View > Master locking levels. Select the locking

Strany 126

Manual – LDB 1.5 Page 7 7 1.0 Commissioning 1.1 Standard toolbar / button functions Comment [WS1]: Need to redu this to change „

Strany 127

Manual – LDB 1.5 Page 70 70 Confirm the new one by entering it a second time, then click OK. Finally, close the Master levels window by clickin

Strany 128

Manual – LDB 1.5 Page 71 71 6.0 Retrieving data from a component 6.1 Retrieving data from a lock Position the lock in front of the Configurat

Strany 129

Manual – LDB 1.5 Page 72 726.2 Retrieving transponder lists This shows you the authorized transponders. Position the Configuration tool in front

Strany 130

Manual – LDB 1.5 Page 73 73 Unauthorized, unsuccessful access attempts can also be logged (see section 4.1). They appear in the list with the co

Strany 131

Manual – LDB 1.5 Page 74 74 This will give you an overview of the most recent access events. You can set the number of saved accesses between 0

Strany 132

Manual – LDB 1.5 Page 75 75 Transponders with validity periods contain the following additional data: Activation date, if set – when the transp

Strany 133

Manual – LDB 1.5 Page 76 76 7.0 Passwords 7.1 Changing the Lock System password Open the Lock System. Click on the bar containing the name of

Strany 134

Manual – LDB 1.5 Page 77 777.2 Password for access monitoring For data protection reasons, certain people are often not permitted to obtain acc

Strany 135

Manual – LDB 1.5 Page 78 78 Click OK.

Strany 136

Manual – LDB 1.5 Page 79 79 8.0 Replacing a component 8.1 Replacing a lock If you replace a lock that cannot be reset, then the software will

Strany 137

Manual – LDB 1.5 Page 8 8 1.2 Installing the software System requirements for installing the Lock Plan software: ¾ Windows 98, Windows ME, Wi

Strany 138

Manual – LDB 1.5 Page 80 80 If you would also like to delete the access audit log, then check Delete Access List. Click on Reset. The programmin

Strany 139

Manual – LDB 1.5 Page 81 81 8.4 If a transponder is lost Normally a new transponder is created and the lost transponder blocked. Open your Lo

Strany 140

Manual – LDB 1.5 Page 82 82 Approve your Lock System. Click on the spare transponder so that it is highlighted. Choose Programming > Transpo

Strany 141

Manual – LDB 1.5 Page 83 83 Once successfully programmed, the window can be closed by clicking OK and then Exit. What you do from there depen

Strany 142

Manual – LDB 1.5 Page 84 84 8.5 Resetting a transponder Choose Programming > reset transponder. Hold the transponder in front of the conf

Strany 143

Manual – LDB 1.5 Page 85 85 9.0 Block lock components 9.1 Arming unit (SSM and SSS) The arming unit is used to arm the alarm system. If you w

Strany 144

Manual – LDB 1.5 Page 86 86 The arming unit requires a power supply for programming, which can, for example, be provided using a 9 Volt battery

Strany 145

Manual – LDB 1.5 Page 87 87 Retrieve the data from the block lock components: Programming > Read unknown lock. The type of the component is di

Strany 146

Manual – LDB 1.5 Page 88 88 10.0 Opening, saving, printing . . . 10.1 Opening a file Choose File > Open. Files are normally saved in the f

Strany 147

Manual – LDB 1.5 Page 89 89 10.2 Saving a file Approve your Lock System. Choose File and Save as... In Save as:, select the folder in which yo

Strany 148

Manual – LDB 1.5 Page 9 9Insert the SimonsVoss CD. In Windows Explorer, select the CD-ROM drive and click on Software > System3060 > Englis

Strany 149

Manual – LDB 1.5 Page 90 90 Once you have saved the file with a password, you will not be asked for it the next time. You can change it at any ti

Strany 150

Manual – LDB 1.5 Page 91 91You can change the layout of the Lock Plan by choosing Options and Printer... In the window that opens you can adjust

Strany 151

Manual – LDB 1.5 Page 92 92 If you have already programmed the lock, then you will see the data which the software has retrieved from it, such as

Strany 152

Manual – LDB 1.5 Page 93 93 10.5 Printing labels You can print labels bearing the names of the locks and transponders, which can be used, for

Strany 153

Manual – LDB 1.5 Page 94 94 Define the format of the labels: 64.6 mm x 33.8 mm 48.5 mm x 25.4 mm 88.9 mm x 35.7 mm Page st

Strany 154

Manual – LDB 1.5 Page 95 95 11.0 Additional functions 11.1 Find and move You can look for Lock Systems, locks and transponders using Edit >

Strany 155

Manual – LDB 1.5 Page 96 96 11.3 Changing names Open your Lock System with Authorize > Open Lock System. Click on the lock or transponder w

Strany 156

Manual – LDB 1.5 Page 97 9711.4 Performing emergency opening If there is no authorized transponder available, you can perform an emergency openi

Strany 157

Manual – LDB 1.5 Page 98 98 11.6 Deactivate Storage Mode Digital US Locks containing software version 10.0 and higher are delivered in an energ

Strany 158

Manual – LDB 1.5 Page 99 99 12.0 Importing and exporting 12.1 Exporting and importing to and from Palm & Pocket PC databases You will fin