Zobrazit stránku 0
SMART RELAIS 2 3063
SREL, SREL.ZK, SREL.ADV, SREL2
Version: August 2012
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - SMART RELAIS 2 3063

SMART RELAIS 2 3063 SREL, SREL.ZK, SREL.ADV, SREL2 Version: August 2012

Strany 2

SMART RELAY SREL, SREL.ZK, SREL.ADV 106.3 DESCRIPTIONS OF CONNECTIONS IN SREL, SREL.ZK AND SREL Name Symbol Description Mains adapter + / ~ Ei

Strany 3

SMART RELAY SREL, SREL.ZK, SREL.ADV 117.0 Programming and configuration If Smart Relay is selected as the lock type in the SimonsVoss software (

Strany 4 - 2.0 Product Description

SMART RELAY SREL, SREL.ZK, SREL.ADV 127.1 ACCESS CONTROL Only possible in SREL.ZK und SREL.ADV versions. The 1,024 most recent trans-ponder trans

Strany 5 - 3.0 Before placing an order

SMART RELAY SREL, SREL.ZK, SREL.ADV 13If you select time switchover, the following options are available to you in the 'Time-controlled switc

Strany 6 - 4.0 Before installation

SMART RELAY SREL, SREL.ZK, SREL.ADV 147.7.1 SMART RELAY IN OMRON MODE + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetzteil{Relais

Strany 7

SMART RELAY SREL, SREL.ZK, SREL.ADV 157.7.2 NO AUDIBLE PROGRAMMING ACKNOWLEDGEMENT SIGNALS SREL.ADV only You should check this field if you do

Strany 8 - 5.0 Installation

SMART RELAY SREL, SREL.ZK, SREL.ADV 167.7.7 INTERFACE For SREL.ADV only You can enter the type of card reader here which the Smart Relay is to s

Strany 9 - 6.0 Terminal Assignment

SMART RELAY SREL, SREL.ZK, SREL.ADV 17 If the current for the external component is greater than 10 mA, this component must be

Strany 10

SMART RELAY SREL, SREL.ZK, SREL.ADV 187.7.10 LOGGING UNAUTHORISED ATTEMPTED ACCESS EVENTS Only for SREL.ZK und SREL.ADV Normally, only authoris

Strany 11

SMART RELAY SREL, SREL.ZK, SREL.ADV 198.1 WIEGAND INTERFACE (33 BIT AND 26 BIT) + / ~- / ~NCCOMNOBrownWhiteGreenGreyYellowBatterie SREL.BATNetz

Strany 12

SMART RELAY SREL, SREL.ZK, SREL.ADV 1.0 IMPORTANT INSTRUCTIONS...4 2.0 PRODUCT DESCRIPTION..

Strany 13

SMART RELAY SREL, SREL.ZK, SREL.ADV 208.2 KABA BENZING, SIEMENS, GANTNER LEGIC, PRIMION, ISGUS INTERFACE + / ~- / ~NCCOMNOBrownWhiteGreenGreyYel

Strany 14 - F3 F2 F1

SMART RELAY SREL, SREL.ZK, SREL.ADV 219.0 Maintenance 9.1 BATTERY WARNING AND BATTERY REPLACEMENT WHEN THE BATTERY SREL.BAT IS USED A Smart Re

Strany 15

SMART RELAY SREL, SREL.ZK, SREL.ADV 2210.0 Technical data for SREL Housing made of black plastic: dimen-sions l x w x h 72 x 57 x 25.5 mm Prot

Strany 16

SMART RELAY SREL, SREL.ZK, SREL.ADV 2311.0 Smart Relay 2 11.1 SMART RELAY 2 VERSIONS SREL2.G2.W: The SREL2 is basically used with transponde

Strany 17 - Externe Antenne

SMART RELAY SREL, SREL.ZK, SREL.ADV 24Use of the backup battery (CR1220 Sony) is described in Section 4.1. 11.2 CARD READER VERSIONS IN CONJUNCT

Strany 18

SMART RELAY SREL, SREL.ZK, SREL.ADV 2512.0 Description of the SREL2 connections Name Symbol Description Mains adapter + DC Direct current 9 to

Strany 19

SMART RELAY SREL, SREL.ZK, SREL.ADV 2613.0 Technical data for SREL2 Housing made of white plastic: dimen-sions l x w x h Semi-transparent base p

Strany 20

SMART RELAY SREL, SREL.ZK, SREL.ADV 27

Strany 21 - 9.0 Maintenance

SMART RELAY SREL, SREL.ZK, SREL.ADV 2814.0 PRODUCT DESCRIPTION 14.1 ORDER CODE WN.CN.UR.SCHALT, referred to as INPUT NODE below. 1.2 HIGHER

Strany 22

SMART RELAY SREL, SREL.ZK, SREL.ADV 7.7.8 Limited range... 16

Strany 23 - 11.0 Smart Relay 2

SMART RELAY SREL, SREL.ZK, SREL.ADV 41.0 Important instructions Safety Instruction: Warning: – The batteries used in this product may pose a f

Strany 24

SMART RELAY SREL, SREL.ZK, SREL.ADV 53.0 Before placing an order 3.1 YOU NEED TO ESTABLISH WHICH VERSION OF SMART RELAY IS REQUIRED Smart Rela

Strany 25

SMART RELAY SREL, SREL.ZK, SREL.ADV 6 Warning! Do not use switching power supplies near Smart Relays. All mains adaptors are to be provided by the

Strany 26

SMART RELAY SREL, SREL.ZK, SREL.ADV 7Backup Batterie nur einsetzen, wenn das Smart Relais mitNetzteil betrieben wird, bei Betrieb mit SREL.BAT die

Strany 27

SMART RELAY SREL, SREL.ZK, SREL.ADV 85.0 Installation  Switch off the power supply (disconnect the plug or battery if necessary).  Connect

Strany 28 - 15.0 WARNING

SMART RELAY SREL, SREL.ZK, SREL.ADV 96.0 Terminal Assignment 6.1 SREL AND SREL.ZK + / ~- / ~NCCOMNOB 6.2 SREL.ADV