Simons Voss Technologies Palm LDB Version 1.40 Servisní příručka Strana 21

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 20
SMART RELAY SREL, SREL.ZK, SREL.ADV
21
9.0 Maintenance
9.1 BATTERY WARNING AND BATTERY REPLACEMENT WHEN THE BATTERY
SREL.BAT IS USED
A Smart Relay can emit a battery warning as follows when the battery capacity is de-
pleted:
SREL, SREL.ZK, SREL.ADV
Inside LED flashes 8x each time a transponder is used and before the relay
switches.
This LED should be visible from the outside in the case of battery-powered
operation.
SREL.ADV only
External LED flashes 8x or external buzzer beeps 8x each time a transponder
is used.
Around another 100 transactions are possible after a battery warning; the bat-
tery should thus be replaced as soon as possible.
9.2 BACKUP BATTERY
A discharged backup battery may lead to the internal clock stopping in Smart Relay
types SREL.ZK and SREL.ADV. We therefore recommend checking the time on the
clock at regular intervals. A backup battery will last for about ten years if the power
supply to the Smart Relay is not interrupted. If Smart Relay draws on the backup bat-
tery at regular intervals due to frequent power failures, this battery should be replaced
on a periodical basis.
If Smart Relay is powered by a battery (SREL.BAT), the backup battery must not
be
used.